PEM Electrolyzer 200

PEM Electrolyzer 200

ELECTROLYZER DATA
No. Cells 10
PHYSICAL PROPERTIES
Universal Gas Constant R [J/(mol K)] 8.314
Temperature T [K] 298
amb. Pressure p [hPa] 1013
Faraday Constant F [As/mol] 96,485.33
PROPERTIES HYDROGEN
Valence z 2
net calorific Value Hu [MJ/m³] 10.79
gross calorific Value Hs [MJ/m³] 12.75
Number MEASUREMENT [EXAMPLE]
VOLTAGE STACK VOLTAGE CELL CURRENT HYDROGEN MASSFLOW TOTAL HYDROGEN MASSFLOW CELL
[V] [V] [A] [cm³/s] [cm³/s]
1 25 2.5 0 0 0
2 25 2.5 0.5 0.3 0.03
3 25 2.5 1 0.6 0.06
4 25 2.5 1.5 0.9 0.09
5 25 2.5 2 1.2 0.12
6 25 2.5 2.5 1.5 0.15
7 25 2.5 3 1.8 0.18
8 25 2.5 3.5 2.1 0.21
9 25 2.5 4 2.4 0.24
10 25 2.5 4.5 2.7 0.27
11 25 2.5 5 3 0.30
Number CALCULATION
POWER INPUT HYDROGEN MASSFLOW FARADAY POWER FARADAY [Hu] POWER HYDROGEN [Hs] POWER HYDROGEN [Hu]
[W] [cm³/s] [W] [W] [W]
1 0.0 0.00 0.0 0.0 0.0
2 1.3 0.06 0.7 0.4 0.3
3 2.5 0.13 1.4 0.8 0.6
4 3.8 0.19 2.1 1.1 1.0
5 5.0 0.25 2.7 1.5 1.3
6 6.3 0.32 3.4 1.9 1.6
7 7.5 0.38 4.1 2.3 1.9
8 8.8 0.44 4.8 2.7 2.6
9 10.0 0.51 5.5 3.1 2.6
10 11.3 0.57 6.2 3.4 2.9
11 12.5 0.63 6.8 3.8 3.2

Hydrogen Chart

Electrolyzer Effiziency

* Hinweis: Das Diagramm enthält nur Beispieldaten. Die tatsächlichen Daten sind maßgebend.

Compliant with Directive 2006/42/EC

• Conforms to DIN EN ISO 12100 – Safety of Machinery: General design principles, risk assessment, and risk reduction

• Equipped with SIEMENS SMART industrial-grade PLC control system

• Integrated multi-level safety monitoring

• Hydrogen stored in solid-state, low-pressure (< 1.6 MPa) containers

• Comprehensive, standards-compliant, and modern didactic documentation

• IoT (Internet of Things) enabled

All processes presented in a practical, clear, illustrative, and calculable way – fully digitally traceable

The system is clearly structured and robustly built, enabling pupils and students to carry out hands-on experiments under clear didactic guidance. This approach allows them to gain an engaging and memorable understanding of hydrogen by directly combining theory with practice.

Up to 500ml/min Production efficiency.

Up to 250W Electricity consumption.

 

Device Specification Unit Value
PEM Electrolyzer Hydrogen Output ml/min 500
Oxygen Output ml/min 250
Power Supply Voltage V 9
Power Supply Current A 25

Water to H2 Production up to 500ml/min. Hands-on practice, digitally traceable.

Contact us

    1. Diese Seite wird zur Sicherheit mit SSL-TLS übertragen und kann von Dritten nicht gelesen werden.
    2. Zur Beantwortung Ihrer Nachricht per E-Mail, speichern wir Ihre Daten. Für andere Zwecke werden die Daten nicht verwendet und auch nicht an Dritte weitergeleitet. Sie können die Speicherung unter der im Impressum eingetragenen E-Mail Adresse jederzeit widerrufen. Sie erklären sich damit einverstanden, dass Ihre Daten zur Bearbeitung Ihres Anliegens verwendet werden. Weitere Informationen und Widerrufshinweise finden Sie in der Datenschutzerklärung.